HOME >Performance result > Actual construction |
|
|
|
Incinerator, boiler( Vertical merge type, water tube type 2 Drum) and prevention facility design, erection, installation construction |
|
Mirae Paper Inc. |
|
24ton/day |
|
JunJoo, JunBook |
|
Mirae Paper Inc. |
|
03.2010 |
|
07.2010 |
|
Stoker +
SNCR + Boiler(Water tube type, 2Drum) - Cyclone - I.D Fan - Venturi
Scrubber - Packed Tower(1st) - Packed Tower(2nd) - Gas
Condenser - Stack- Boiler capacity: 8ton/hr (15kg/㎠.g) - Steam generation amount : 6.5ton/hr (12kg/㎠.g) - Feed water temperature : 100℃ - Energy recovery efficiency : 78.3% (Korea institute of Machinery and
Materials, 11. 2010) ※ Korea’s first private industry site high
efficiency stoker incinerator installation
|
|
|
|
|
|
|
|